When EE:EE appears on the display panel, press and hold both “Energy Save” and “Zone Control” buttons simultaneously for 3 seconds. After a moment, the error code will be shown on the screen.
| Error Code | Description |
|---|---|
| E0:00 | Communication error – indoor unit to remote |
| E1:00 | Communication error – indoor unit to outdoor unit |
| E2:00 | Return air thermistor open circuit |
| E3:00 | Return air thermistor short circuit |
| E4:00 | Indoor coil thermistor open circuit |
| E5:00 | Indoor coil thermistor short circuit |
| E6:00 | Outdoor coil thermistor open circuit |
| E7:00 | Outdoor coil thermistor short circuit |
| EA:00 | Outdoor ambient thermistor open circuit |
| Eb:00 | Outdoor ambient thermistor short circuit |
| Ec:00 | Discharge pipe thermistor open circuit |
| Ed:00 | Discharge pipe thermistor short circuit |
| EE:00 | High pressure problem |
| EF:00 | Discharge pipe temperature problem – too high (possible refrigerant shortage) |
To return to normal operation mode, press and hold the “Energy Save” and “Zone Control” buttons again for 3 seconds.